Cable Leading Covered Chains

SCOPE OF APPLICATION

The closed type of cable leading chains, are intended to protect the moving cables and hoses (used in hydraulics and pneumatics) against external influences in their reciprocating movement in a horizontal or vertical plane and also in combined movement. They provide:

  • a reliable protection against external influences
  • a longer lifetime
  • a silent movement
  • safety at work

 

CONDITION OF OPERATION

For normal operation of cable leading chains is necessary to respect the following conditions:

  • speed-limit of 20 m/min
  • ambient temperature of- 5-50°С
  • humidity environment- below 60%

Crossing and interweaving of cables in cable leading chains is not allowed, and the space within the chain should be filled with cables less then 80%. Creep and friction with machine surfaces are not allowed.

TECHNICAL CHARACTERISTICS

FORMULA FOR CALCULATING THE LENGTH OF THE CABLE LEADING CHAIN

L=Ls/2+4R+50

Type A B C D P R
+0%
-20%
RA H Ls max.
includes pre-tensioning unsupported supported
0.0 30 20 26 16 25 55 120 144 2000 4000
1.0 50 30 43 23 30 72
110
165
150
235
345
104
269
379
3000 6000
1.1 50 50 45 45 50 110 240 294 4000 8000
2.0 80 45 73 38 45 110
220
275
140
260
370
290
510
620
4000 8000
2.1 85 60 80 55 65 165 350 415 5000 10000
2.2 95 50 90 45 60 155 330 385 4000 8000
3.0 110 60 102 52 60 155
250
330
335
525
685
400
590
750
5000 10000
3.1 115 80 109 74 80 220 465 550 5000 10000
4.0 170 80 162 72 80 205 435 520 5000 10000
4.1 175 110 167 102 80 285 600 717 5000 10000
A x B Outside cross-section
С x D Inside cross-section
Ls Move (traveled distance)
L Free lenght
R Bending radius
H Height of installation
P Depth/Level of flange attachement
Lowest support height
F Reinforcing tape

 

TYPES OF FLANGES

IMPLEMENTATION, DEPENING ON THE LOCATION OF THE FLANGES:

There is a resistance spot welding between the flanges, the outer tube and the reinforcing tape. It must provide an electrical resistance below 10 ohms.

Both chain flanges must be grounded to the common grounding of the machine, according to the requirements of Technical safety regulations.

 